Merge pull request #15820 from oleg-alexandrov:patch-1

Clarify stereoRectify() doc

The function stereoRectify() takes as input a coordinate transform between two cameras. It is ambiguous how it goes. I clarified that it goes from the second camera to the first.
pull/15838/head
Oleg Alexandrov 5 years ago committed by Alexander Alekhin
parent 4e156a162f
commit d56535afce
  1. 4
      modules/calib3d/include/opencv2/calib3d.hpp

@ -1543,8 +1543,8 @@ CV_EXPORTS_W double stereoCalibrate( InputArrayOfArrays objectPoints,
@param cameraMatrix2 Second camera matrix.
@param distCoeffs2 Second camera distortion parameters.
@param imageSize Size of the image used for stereo calibration.
@param R Rotation matrix between the coordinate systems of the first and the second cameras.
@param T Translation vector between coordinate systems of the cameras.
@param R Rotation matrix from the coordinate system of the second camera to the first.
@param T Translation vector from the coordinate system of the second camera to the first.
@param R1 Output 3x3 rectification transform (rotation matrix) for the first camera.
@param R2 Output 3x3 rectification transform (rotation matrix) for the second camera.
@param P1 Output 3x4 projection matrix in the new (rectified) coordinate systems for the first