This does force a number of uses of `# pylint: disable` comments, but it
also finds a couple of useless global uses and one place (in the
previous commit) that an easy refactor removes the use of global. Global
is a code smell, so forcing adding a comment to disable helps force
developers to really consider if what they're doing is a good idea.
The `global` statement is only needed to assign to global variables, not
read or mutate them. So calling `global.mutate()` is fine, but not
`var = foo`, which would otherwise shadow `var`.
Using future annotations, type annotations become strings at runtime and
don't impact performance. This is not possible to do with T.cast though,
because it is a function argument instead of an annotation.
Quote the type argument everywhere in order to have the same effect as
future annotations. This also allows linters to better detect in some
cases that a given import is typing-only.
we return _log even though this entire family of functions returns None,
because a side effect of returning is that the other version of the
function is not run.
We can do that more obviously, using an else clause that doesn't attach
meaning to return values.
This reverts commit 5fcb0e6525.
The commit is a massive change that should have been split in
separate pieces, and it also removes a few features:
* in verbose mode, subtests are not printed as they happen
* in non-verbose mode the progress report does not include the
number of subtests that have been run
* in non-parallel mode, output is batched rather than printed as
it happens
Furthermore, none of these changes are not documented in the release
notes. Revert so that each proposal can be tested, evaluated and
documented individually.
This change set aims to fix various "issues" seen with the current
implementation. The changes can be summarized with the following list:
* Replace emojis and spinners with multiline status displaying the name
and running time of each currently running test.
* The test output (especially in verbose mode or when multiple failing
tests' output gets printed out) can get confusing. Try to make the
output easier to read and grasp. Most notable change here is the
addition of the test number to the beginning of each printed line.
* Print exit details (i.e. exit code) of the test in verbose mode.
* Try to make the verbose "live" output from tests to match the look and
feel of otherwise produced (verbose) test output.
Since it cannot resolve `import typing as T` in order to figure out that
T.* is doing annotation-worthy stuff.
Since T.cast('Foo') is not actually using Foo except in an annotation
context (due to being a string) it requires extra work to resolve, and
the only thing that would currently work is actually using
'typing.cast'. However, we have decided to not use it except as T...
Since this import is only imported during mypy it's not so bad to noqa
it.
Dependencies are currently printed as
[<mesonbuild.mlog.AnsiDecorator object at 0x7faa85aeac70>, ' ', <mesonbuild.mlog.AnsiDecorator object at 0x7faa85aeab50>]
This was introduced in commit adb1b2f3f6, due to
an incorrect type annotation on the AnsiText constructor. Fix both the
annotation and the usage.
Signed-off-by: Paolo Bonzini <pbonzini@redhat.com>
Meson used to prepend '|' for each nested subproject to distinguish in
the logs where a subproject start and ends. It is more useful to print
the current subproject name.
Also print the call stack when starting a new subproject to better see
which subproject chain leads to to.
All changes were created by running
"pyupgrade --py3-only --keep-percent-format"
and committing the results. I have not touched string formatting for
now.
- use set literals
- simplify .format() parameter naming
- remove __future__
- remove default "r" mode for open()
- use OSError rather than compatibility aliases
- remove stray parentheses in function(generator) scopes
Automatically colorize the text when printing the AnsiDecorator, based
on the result of mlog.colorize_console(). This is how AnsiDecorator
is used most of the time anyway.
Avoid calling self.collected_failures.append twice, and avoid
inflated indentation by adding a "plain" decorator to mlog.
Fixes: ba71fde18 ("mtest: collect failures regardless of colorized console", 2020-10-12)
This will be printed in bold at the end of interactive meson
sub-commands that won't be parsed by a program. Specifically: setup,
compile, test, and install.
NOTICE: You are using [...]
Some warnings are out of the user's control, such as the RCC QT bug,
or the GNU windres bug, or our informational warning about
auto-disabling of options when -Db_bitcode is enabled.
Such warnings should not be fatal when --fatal-meson-warnings is
passed because there's no action that the user can take to fix it. The
only purpose it serves is to prevent people who use those features
from using --fatal-meson-warnings.
D lang compilers have an option -release (or similar) which turns off
asserts, contracts, and other runtime type checking. This patch wires
that up to the b_ndebug flag.
Fixes#7082
Currently, colourize_console is a constant, set at process
initialization.
To allow the actual stdout to be easily compared with the expected when
running tests, we want to allow colourization to be on for the test
driver, but not for the in-process configure done by run_configure,
which has stdout redirected from a tty to a pipe.
v2:
Cache _colorize_console per file object
v3:
Reset cache on setup_console()
getattr() requires a default (return if missing) value or it raises an
AttributeError. In a few cases I changed hasattr to getattr and didn't
set a default value, so those cases could except. This corrects that.
There were two things mypy was warning about:
1) it doesn't understand hasattr()
2) It was possible for mlog.{error,warning,deprecation} to get passed
multiple values for the once keyword argument.
Warnings have a location node object (with subdir and lineno
attributes), which is passed as a location: kwarg to mlog.warning() and
formatted in _log_error().
Re-purpose the subdir attribute (path relative to the source root dir,
with an implied filename of 'meson.build'), which is stored into the
node by parser(), to contain a pathname.
(Properly I should rename 'subdir' -> 'file' everywhere, but that's a
lot of churn just to see if this works)
Notes:
The warning location node may also have a colno attribute, which is
currently ignored by _log_error().
We can't currently issue warnings with locations in meson_options.txt
because the filename isn't part of the location (as it's assumed to be
'meson.build).
This adds a warnings counter for subprojects that passed. This is to
encourage developpers to check warnings in the logs and hopefully fix
them. Otherwise they could be hidden in hundreds lines of logs.
This also print the error message for subprojects that did not pass. The
error message is often enough to fix the issue (e.g. missing
dependency) and it's easier than searching in the logs why a subproject
failed.